Building Performance
Testing

Comprehensive diagnostic testing for building envelopes and HVAC systems. AAMA Certified Fenestration Master and BPI Certified tester on every project.

3Core testing
disciplines
AAMA

Certified Fenestration Master

BPI

Certified Blower Door / Duct Tester

ASTM

E1105 · E783 · E779 standard test methods

What We Test

Windows (ASTM E1105)Air leakage (ASTM E783)Doors & skylightsCurtain wallsStorefrontsAir barriersDuct systemsBlower door

AAMA/ASTM Window Testing

Water penetration testing per AAMA 502/503 and ASTM E1105 to verify window and door performance. We test installed fenestration products for water resistance under controlled pressure differentials, identifying installation defects and product failures.

AAMA 502AAMA 503ASTM E1105ASTM E783

Scope

  • Installed window & door water penetration testing
  • Air infiltration testing of fenestration products
  • Curtain wall and storefront system testing
  • Post-construction quality assurance testing
  • Warranty claim documentation and support

Blower Door Testing

Whole-building air leakage testing to measure the airtightness of building envelopes. Our BPI-certified blower door tests quantify air infiltration rates and identify air leakage pathways when combined with infrared thermal imaging.

ASTM E779RESNET/ICC 380

Scope

  • Whole-building air leakage measurement
  • Air leakage site identification with IR imaging
  • Energy code compliance verification
  • Pre- and post-remediation testing
  • Multi-zone pressure diagnostics

Duct Leakage Testing

HVAC duct system leakage testing to verify ductwork integrity. Leaky ducts waste energy, compromise indoor air quality, and create pressure imbalances that drive moisture into building assemblies.

SMACNA Duct LeakageASHRAE 90.1

Scope

  • Total duct leakage measurement
  • Duct leakage to outside measurement
  • New construction duct verification
  • Energy audit duct assessment
  • HVAC system performance diagnostics

Why Choose Certified Testing

Certified Professionals

AAMA Certified Fenestration Master and BPI Certified tester on every project — the highest credentials in the industry.

Defensible Reports

Detailed documentation that satisfies warranty claims, insurance requirements, and litigation support needs.

Energy Savings

Quantify air leakage and duct losses to prioritize the improvements with the biggest energy impact.

Code Compliance

Verify building envelope performance meets Florida Building Code, IECC, and project-specific requirements.

Need Building Performance Testing?